Purpose
Signal lamp LS-04 falls into group I, category M1 of equipment which is designed for continous work in underground mines and sufrace facilities with a possibility of methane explosions, as well as in surface mine facilities and confined space work where potential explosive atmosphere of mine gas (methane) and/or coal dust can occur temporarily in general work conditions.
Falls into group III, category 2G of equipment which is designed for continuous work in 1 and 2 zones endangered by gases, vapor and mist of group IIB.
It is a warning device adjusted to work with position casings OP-1 which are used to indicate the end of mine trains.
Major advantages:
Spark-proof design ( level "ia ").
Maintenance free, gasproof, battery Ni-MH (so called "hydrogen")
High capacity lighting achieved owing to LED diode system with high intensity luminosity
Battery might be carried on the belt
Technical data
| Mass of lamp |
0,9 kg |
| Time of burning |
16h |
| White diode luminous intensity |
1500 lx |
| Explosion-proof construction feature |
 I M1 Ex ia I
 II 2G Ex ia IIB 120° C(T4) |
| Rated voltage of battery |
3,6 V (3 x Ni-MH 1,2V) |
| Rated ampere-hour capacity of battery |
|
Rated duration
(number of charging /discharging cycles) |
min. 800 cycles |
| Charging time |
max. 6 h |
| Light source |
1 white LED diode and 12 red diodes |
| Light source life |
100 000 h |
|
Overall dimensions (l x b x h) of battery |
140mm x 61mm x 55mm
|
| Range of the cable length |
500 - 1600 mm (standard 600 mm) |
| Housing protection degree |
IP 65/IP67 |
Over-current protection
|
fuse WBO-1,6A
|
| Range of working temperature |
-20°C to +40°C |
| |
|
| Certificate of EC type examination: |
KDB 10ATEX100X |
| Certificates |
94/9WE(ATEX) 2004 /108/WE (EMC) |
| |
|
| Charging |
multiple station charging units LLK-_ single station charging units LU-1*L06H
|
| |
|
 |
|
|