| LN-IZA 938*GL | LN-IZA 938*LO | LN-IZA 938*ND | LN-IZA 938*NS | |
| Rated voltage of battery | 3,6 V (3 x Ni-MH 1,2 V) | |||
| Rated ampere-hour capacity of battery | min. 4,0 Ah | |||
| Rated duration (number of charging /discharging cycles) | min. 800 cycles | |||
| Light source D1 - main light source (In the lamp head) D2 - auxiliary light source (In the battery cover) |
D1, D2 | D1 | ||
| Light source life | 100 000 h | |||
| Number of light source positions (optional configurations) | 2 | |||
| Usable lamp burning time (time of burning / luminous intensity) | - | |||
| Position 1 diode LED D1 (light at decreased brightness) |
min. 16 h / min. 900 lx | min. 24 h / min. 900 lx | ||
| Position 2 (main light source -according PN-EN 62013-2) diode LED D1 (full light 100%) |
min. 10 h / min. 1800 lx | min. 16 h / min. 1800 lx | ||
| Location transmitter | GLON5S | LOK5S | - | |
| Visual signaling of transmitter operation | yes | - | ||
| Duration of location transmitter | min. 170 h | - | ||
| Housing protection degree | IP65 / IP67 (according to PN-EN 60529:2003) |
|||
| Mass of lamp | about 1 kg | about 0,9 kg | ||
| Overall dimensions (l x b x h) of battery | 115 mm x 46 mm x 93 mm | |||
| Length of the cable – standard (range of the cable length) |
1400 ±20 mm (from 1100 mm to 1600 mm ) |
|||
| Over-current protection | Fuse WBO-1,6 A | |||
| Range of working temperature | -5 °C ÷ +40 °C | -20 °C ÷ +40 °C | ||
| Charging time | max. 6 h | |||
| Category of the equipment emitting optical radiation (according PN-EN 60825-1) |
Class 2M | |||
| Explosion-proof construction mark | I M1 Ex ia I II 2G Ex ia IIB T4 |
|||
| Certificate of EC type examination | KDB 09ATEX130X | |||
| CERTIFICATES | Certificate of Conformity with Directive: - 94/9/WE (Directive ATEX) - 2004/108/WE (Directive EMC) |
|||