Purpose.
The
FP-100N combined filter is fixed to RM 200 & RM-300 type filtration
-ventilation device and designed for air cleaning from toxic chemical
compounds, radioactive dust and bactericides.
The FP-100N combined filter when fixed into the filtration-ventilation
device can be used in the
stationary shelters and another stationary facilities where there
is a need of breathable clean air.
Technical data
| -
nominale rate of flow |
100 m3/h |
| -
initial resistance at nominal rate of flow |
650
Pa |
| -
effectiveness of filtration |
99,999% |
| -
leak tightness degree at positive pressure of 2000 Pa
for nominal rate of flow |
0,5 l/min |
| - mass
max. |
30
kg |
-
absorbing capacity in accordance with WT-428
item 3.1.5. i 3.1.6. |
|
| |
|
| Environmental
conditions ( during operation ) |
|
| temperature
|
-30 0C
÷ +500C |
Advantages
-
wide
range of usable temperature
-
effectivness of filtration
- small
overall dimensions
- simple
assembly
- wide
range of application
The
FP-100N combined filter has the certificate of conformity No 3/02 issued
by Center for Goods Certification of Military Institute of Chemistry
and Radiometry WICHiR in Warsaw,POLAND.
back
|