CAP LAMP LN-10
LN-10*GLON3S, LN-10*LOK3S, LN-10*N



Application:

The LN-10 cap lamp is an intrinsically safe lamp that can be used in underground mines where
there is a possibility of methane explosions.The cap lamp is designed for maintenance free charging,
operation is easy and gives excellent illumination in differen work situations.

  

Design:

The LN-10 cap lamp consists of a battery housing and head , connected together by means of cable.
A technologically advanced high intensity diode lamp instead of a traditional bulb providesource.
A battery housing consists of the battery and the outer cover. Depending on the version,
cap lamps differ in external covers and location transmitter. The battery consists of four tightly closed
Ni-MH 8.5Ah/1.2V cells.

 

Specificatio:

 
Type of lamp
Parameter
LN-10*GLON3S
LN-10*LOK3S
LN-10*N
mass lamp
1,5 kg
1,5 kg
1,4 kg
usable lamp burning time ( time of burning )
- for diode LED 3W - full light
 - light at lower intensity
 
12 h ±5%
24 h ± 5%
 
min. 16 h
min. 40 h
location transmitter
GLON3S
LOK3S
 -
duration of location transmitter
min 170 h
-
explosion-proof construction mark
I M2 Ex I PN-EN 62013-1
EEX ibI
I M2 Ex I
PN-EN 62013-1

reted voltage of battery
4,8 V (4 xNi-MH 1,2V)
rated ampere-hour capacity of battery
8,5 Ah
power consumption from the battery
( average value) for main source of light-full light
0,5 A
rated duration ( number of charging / discharging cycles )
min. 800 cyclesi
light source ( main & au7xiliary )
2 x diode LED ( 3W & 1 W )
luminous intensity - main light source
( according to PN-EN 62013-2 )
min. 100 000 h
overall dimensions ( l x b x h )
160mm x 60mm x 105mm
lengh of the cable
1400 mm
housing protection degree
IP 65/IP 67
( according to PN-EN 60529:2003 )
overcurrent protection
fuse WBO-1.6 A + overcurrent switch
range of working temperature
od -5°C do +40°C
   
conformity with Standards
PN-EN 62013-1 : 2003 (U);
 
PN-EN 62013-2 : 2004 (U);
 
PN-EN 50014 : 2002 (U);
 
PN-EN 50020 : 2003 (U);
 
PN-EN 61547:2002
 
PN-EN 55015:2005
   
 
certificate of type test WE
KDB 04ATEX211X/1
It is recommended to use charging units LLD type produced by FASER S.A to charge the cap
lamps LN-10.*.....type.
 
 

 