ROOM CONVENTIONAL GAS HEATER OGK-F


Ogrzewacze


APPLICATION

Room convectional gas hether serve a purpose of warning up room`s (offices, cottages, shops, etc.)


PRINCIPLE OF OPERTION

Room conventional gas heathers OGK-F 1,8; 3,3; 4,2 are equipped with closed combustion chamber (type C). The heat is given up into the room by way of natural convection. The air which is conveyed and the exhaust gases are emitted into the atmosphere by means of air-exhaust gas pipe. Starting up of gas heater is caried out by means of piezo-elestric igniter through the ingition of lighting-up burner. The main burner is lighted up as soon as the termoregulator is properly set up.


TECHNICAL DATA

 
TYP OGK-F 1,8 OGK-F 3,3 OGK-F 4,2
Thermal power of burner (kW) 1,8 3,3 4,2
Rated gas consumption for :

GZ-50 (m3/h)

GZ-35 (m3/h)

Technical propane (m3/h)

Technical propane (kg/h)

 

0,2

0,3

0,08

0,15

 

0,4

0,5

0,15

0,24

 

0,5

0,6

0,17

0,31

Efficiency (%) 85 86 86
Diameter of connector R 1/2  R 1/2  R 1/2 
Diameter of air-exhaust gas pipes (mm)

air intanke ø 

exhaust gas outlet ø

Lenght of the air-exhaust gas pipes (mm)

air intanke ø 

exhaust gas outlet ø

 
 

150

70
 
 
 

650

700

 
 

175

100
 
 
 

650

700

 
 

175

100
 
 
 

650

700

Dimensions (mm)

lenght

height

widht

 

410

500

130

 

750

400

180

 

750

400

180

Mass (kg) 12 20 20

Ogrzewacz


<<--back