Time of protective functioning at
air consumption of 30 dm³/min:
|
|
| - total |
20min |
| - without reserve air |
16min |
| Number of cylinders of apparatus |
1 |
| Cylinder capacity / Cylinder diameter: |
2 dm³/103mm |
|
Maximal cylinder filling pressure |
30 Mpa |
|
Air reserve in cylinder: |
600 dm ³ |
| System of pressure reduction: |
two-stage system with separate reduction stages |
| Reduced pressure: |
0,67-0,75 Mpa |
| Demand valve joint: |
Rd40x1/7 or M45x3 or a quick connector |
|
Warning signal activation pressure: |
5,5 ± 0,5 Mpa |
Capacity of demand valve
at negative pressure of 1000Pa |
minimum 300 dm ³/min |
| Inspiration resistance of demand valve dm |
not exceeding 450 Pa |
Mass of apparatus filled
with air and facemask |
5,3kg |
|
Overall dimensions (height x width x thickness): |
454 x 103 x 103m |