| reted voltage of battery |
4,8 V (4 xNi-MH 1,2V) |
| rated ampere-hour capacity of battery |
8,5 Ah |
power consumption from the battery
( average value) for main source of light-full light |
0,5 A |
| rated duration ( number of charging / discharging cycles ) |
min. 800 cycles |
| light source ( main & au7xiliary ) |
2 x diode LED ( 3W & 1 W ) |
| configuration of light source |
4 positions |
| luminous intensity - main light source |
|
( according to PN-EN 62013-2 )
|
min. 100 000 h |
|
|
| overall dimensions ( l x b x h ) |
160mm x 60mm x 105mm |
| lengh of the cable |
from 1100mm to 1600mm (standard version 1400mm) |
| housing protection degree |
IP 65/IP 67
( according to PN-EN 60529:2003 ) |
| overcurrent protection |
fuse WBO-1.6 A + overcurrent switch
|
| range of working temperature |
od -5°C do +40°C |
| |
|
| conformity with Standards |
PN-EN 62013-1:2004, PN- EN 62013-2:2004 |
| |
PN-EN 50014:2004, PN-EN 50020:2005, |
| |
PN-EN 50303:2004, PN- EN 61547:2002, |
| |
PN- EN 55015:2005, PN-EN 60529: 2003 |
| |
|
| certificate of type test WE |
KDB 05ATEX418X/1 |
| |
KDB 05ATEX418X/1 |
| |
KDB 05ATEX418X/2 |
| |
|
| charging period |
max. 10h |
| |
|
It is recommended to use charging units LLD type produced by FASER S.A to charge the cap
lamps LN-10.*.....type.
|
| |
|